Loading...
Disposition of Approval & Application Packet BOZ2021-14 406 Pearl Street N O T I C E FINDINGS AND DECISION OF THE CITY OF BOULDER BOARD OF ZONING ADJUSTMENT DISPOSITION OF ZONING CASE DOCKET NUMBER BOZ2021-00014 CONCERNING THE APPLICATION FOR A SETBACK VARIANCE REQUIREMENTS OF SECTION 9-7-1, B.R.C. 1981 AT 406 PEARL STREET, BOULDER, COLORADO OF DIANA AND ANDREW FORDYCE, WHOSE MAILING ADDRESS IS 406 PEARL STREET, BOULDER, COLORADO, 80302. On October 14, 2021, the City of Boulder Board of Zoning Adjustment, a quorum being present, held a public hearing, after giving notice as required by law, on the application for the following variance: As part of a proposal to move an historic barn structure entirely onto the property and out of the City right-of-way, the applicants are requesting a variance to the west side-adjacent-to-street yard setback (along 4th Street) in order to meet the minimum setback requirements for an accessory structure in the RMX-1 zoning district. The resulting west setback will be approximately .1 feet where 12.5 feet is required and 0 feet exists today considering the structure is currently located off the property by about 2 feet. Section of the Land Use Code to be modified: Section 9-7-1, BRC 1981. Based on our field investigation and the relevant testimony, exhibits, and other evidence introduced at the hearing, and in accordance with the applicable provisions of the Boulder Revised Code, 1981, we find by a preponderance of the evidence that the criteria for granting a variance have been met, and grant the variance as requested: This variance is limited to the use and structure for which it was requested, including the location on the lot and maximum height, as approved by the Board of Zoning Adjustment. This variance was approved by the vote of 5-0. EXECUTED this 14th day of October 2021, effective as of, October 14, 2021. Jill Lester, Presiding Officer of the Board at the Meeting By: ______________ ___________________________ Robbie Wyler, Secretary to the Board of Zoning Adjustment This decision constitutes a final decision as of the date of the hearing at which it was reached. If a variance was granted, the variance expires within 180 (one hundred eighty) days from the date on which it were granted unless a building permit for such variance is applied for within such period. CITY OF BOULDER Planning and Development Services 1739 Broadway, Third Floor • P.O. Box 791, Boulder, Colorado 80306-0791 phone 303-441-1880 • fax 303-441-3241 • email plandevelop@bouldercolorado.gov www.boulderplandevelop.net BOZA Disposition of Approval Page 1 of 13 Revised March 2020 400.pdf City of Boulder Planning and Development Services 1739 Broadway, third floor • PO Box 791 • Boulder, CO 80306 Phone: 303-441-1880 • Fax: 303-441-4241 • Web: boulderplandevelop.net BOARD OF ZONING ADJUSTMENT (BOZA) VARIANCE APPLICATION APPLICATION DEADLINE IS THE SECOND WEDNESDAY OF EACH MONTH. MEETING DATE IS 5:00 P.M. ON THE SECOND THURSDAY OF THE FOLLOWING MONTH. Submittal of inaccurate or incomplete information and materials may result in rejection of the application. STAFF USE ONLY Doc. No. _______________ Date Filed _________________Zone______________Hearing Date _____________ Application received by: Date Fee Paid Sign(s) Provided GENERAL DATA (To be completed in full by the applicant.) •Street Address or General Location of Property: •Legal Description: Lot Block Subdivision (Or attach description.) •Lot Size: •Existing Use of Property: •Detailed Description of Proposal (Specific Variance[s] Requested Including All Pertinent Numerical . Values (e.g.: Existing, Required and Proposed Setbacks for the Subject Setback Variance): *Total gross floor area existing:*Total gross floor area proposed: *Total gross building coverage existing:*Total gross building coverage proposed: *Building height existing:*Building height proposed: *See definitions in Section 9-16-1, B.R.C. 1981. ♦Name of Owner: •Address:Telephone: •City: State: Zip Code: Email: ♦Name of Contact (if other than owner): •Address:Telephone: •City: State: Zip Code: Email: BOZA Disposition of Approval Page 2 of 13 2 APPLICATION TYPES (Check All That Apply For This Application) ‰Setback (BRC 9-7-1) ‰Porch Setback & Size (BRC 9-7-4) ‰Building Separation (BRC 9-7-1) ‰Bulk Plane (BRC 9-7-9) ‰Side Yard Wall Articulation (BRC 9-7-10) ‰Building Coverage (BRC 9-7-11 or BRC 9-10) ‰Floor Area Ratio (BRC 9-8-2) ‰Parking in Front Yard Landscape Setback (BRC 9-7-1 & 9-9-6) ‰Size and Parking Setback Requirements for Accessory Units (BRC 9-6-3) ‰Cumulative Accessory Building Coverage (BRC 9-7-8) ‰Mobile Home Spacing Variance (BRC 9-7-13) ‰Use of Mobile Homes for Non-Residential Purposes (BRC 10-12-6) ‰Solar Exception (BRC 9-9-17) ‰Sign Variance (BRC 9-9-21) BOZA Disposition of Approval Page 3 of 13 3 APPLICATION REQUIREMENTS As a minimum, the following items MUST be attached, collated and hereby made a part of this application: •If applicant is other than owner(s), a written consent of the owner(s) of the property for which the variance is requested; •A written statement thoroughly describing the variance request(s) and addressing all pertinent review criteria for approval - see following pages (3 copies); •A signed and stamped Improvement Location Certificate or Site Improvement Survey and legal description by a registered surveyor (3 copies); •A site development plan including setbacks, building elevations, interior layout/floor plans and any other pertinent exhibits (3 copies); •A demolition plan clearly differentiating between existing/remaining and proposed portions of the structure(s) (3 copies); •Any other information pertinent to the variance request (e.g. neighbor letters, photos, renderings, etc.) (3 copies); •Sign Posting Acknowledgement Form - see following page. NOTE: The applicant is responsible for posting the property in compliance with city requirements. Signs will be provided to the applicant at the time of submission of the application. The applicant will be responsible for posting the required sign(s) within 10 days of the hearing date. Failure to post the required sign(s) may result in the postponement of the hearing date. •An electronic copy of all application materials (including a completed & signed application form) must be submitted on a thumb/USB drive with your application. *CDs will not be accepted; •A Board of Zoning Adjustment application fee (as prescribed in the current ‘Schedule of Fees’ which can be found at bouldercolorado.gov/plan-develop); NOTE: SEE SECTION 9-2-3(l), B.R.C. 1981 FOR VARIANCE EXPIRATION INFORMATION Applicant Signature ______________________________________Date__________ Owner (if other than Applicant) Signature _________________________Date__________ BOZA Disposition of Approval Page 4 of 13 SIGN POSTING REQUIREMENTS APPLICANT’S ACKNOWLEDGMENT FORM Required for Certain Land Use Review, Administrative Review, Technical Document Review, and Board of Zoning Adjustment Applications CITY CODE REQUIREMENT FOR SIGN POSTING OF LAND USE REVIEW APPLICATIONS - Excerpt of Section 9-4-3(c), B.R.C. 1981: Public Notice of Application: The city manager will provide the following public notice of a development review application: (1)Posting: After receiving such application, the manager will cause the property for which the application is filed to be posted with a notice indicating that a development review application has been made, the type of review requested, and that interested persons may obtain more detailed information from the planning department. The notice shall meet the following standards: (A)The notice shall be place on weatherproof signs that have been provided by the City and placed on the property that is the subject of the application. (B)All such notice shall be posted no later than ten days after the date the application is filed to ensure that notice is posted early in the development review process. (C)The signs shall be placed along each abutting street, perpendicular to the direction of travel, in a manner that makes them clearly visible to neighboring residents and passers-by. At least one sign shall be posted on each street frontage. (D)The signs shall remain in place during the period leading up to a decision by the approving authority, but not less than ten days. (E)On or before the date that the approving authority is scheduled to make a decision on the application the city manager will require the applicant to certify in writing that required notice was posted according to the requirements of this section. I, , am filing a Land Use Review, Administrative Review, Technical (PRINT NAME OF APPLICANT OR CONTACT PERSON) Document Review, or BOZA application [on behalf of] (PRINT NAME OF OWNER(S) IF OTHER THAN APPLICANT/CONTACT) for the property located at (PRINT PROPERTY ADDRESS OR LOCATION) . I have read the city's sign posting requirements above and acknowledge and agree to the following: 1.I understand that I must use the sign(s) that the city will provide to me at the time that I file my application. The sign(s) will include information about my application and property location to provide required public notice. 2.I am responsible for ensuring that the sign(s) is posted on the property described above in such a way that meets the requirements of Section 9-4-3(c), B.R.C. 1981 (listed above), including visibility of the sign(s) and time and duration of the sign(s) posting, and including reposting any signs that are removed, damaged, or otherwise displaced from the site. As necessary, I shall obtain a replacement sign(s) from the city for reposting. 3.I understand that certain future changes to my application, including but not limited to, changes to the project description or adding a review type, may require that I post a new sign(s). The city will notify me if such a reposting is required and provide me with a necessary replacement sign(s). 4.I understand that failing to provide the public notice by sign posting required by the city’s land use regulation may result in a delay in the city’s issuing a decision or a legal challenge of any issued decision. NAME OF APPLICANT OR CONTACT PERSON DATE Please keep a copy of this signed form for your reference. If you have any questions about the sign posting requirements or to obtain a replacement sign, please call 303-441-1880. BOZA Disposition of Approval Page 5 of 13 BOZA Written Statement for 406 Pearl Street Boulder, CO 80302 October 01, 2021 To: Board of Zoning Adjustment Re: Written Statement Job Site Address: 406 Pearl Street Boulder, CO 80304 Narrative: We have been working with James and the LDRC to preserve this barn. It is a contributing structure in this historic district. The barn needs a great deal of work and must be moved on to the owner’s property for that to occur. In addition, the owner would like to convert the barn into an ADU. This requires raising the barn 3’-0” so that the floor elevation meets FEMA requirements. We have surveyed the low point at 5389.6’ and surveyed the ridge at 5406.4’ and with the 3’-0 increase it puts the barn at 5409.4’. That makes the barn height at 19.8’. So there is no issue with the peak height. Our request is for a setback variance allowing a zero setback off of the west property line and a 12’-0” setback off of the south property line. We have discussed this at length with James Hewatt and feel this strikes a balance between all parties involved. 1. Item 4: Satisfied by letter from James Hewitt. 2. Item 5 : (A) This request does not alter the essential character of the neighborhood. The LDRC has reviewed this revised location - zero setback off of the west property line and believes this is the optimal location for the barn. (B) This move does not impair the use, enjoyment, or development of adjacent property. (C) This is the minimum variance that affords relief, and is the least modification of the applicable provisions of this title. (D) This variance would not cause any Solar Access Conflicts. BOZA Disposition of Approval Page 6 of 13 MEMORANDUM TO: Board of Zoning Adjustment Brian Holmes, Zoning Administrator Robbie Wyler, Asst. Zoning Administrator FROM: James Hewat, Senior Historic Preservation Planner DATE: August 9th, 2021 RE: Support for requested setback variance at 406 Pearl Street in the West Pearl Historic District. Background Archival research indicates the one and one half-story vernacular house at 406 Pearl Street located in the West Pearl Historic District, to have been constructed prior to 1893 and by 1900 the property was occupied by George L., his wife Alice (nee Stansbury) Harding, and their daughters Eva and Mildred. The 1988 Historic Building Inventory form for the property identifies the house as being “masonry vernacular” and by that time it had “been remodeled beyond its historic integrity”. Located at the rear of the property, the barn appears to have also been constructed in the late-nineteenth century, while the small cottage between the main house and barn was constructed in 1952. Because of significant changes to the main house in the 1970s and because the cottage was constructed in 1952 (and outside the identified 1874-1906 period-of-significance for the West Pearl Historic District), these buildings are not historically contributing. However, the barn is well-preserved to the pre-1906 period, and historically contributing as identified in the 1994 West Pearl Historic Design Guidelines. 406 Pearl Street c.1898 (Carnegie Library for Local Hist.) BOZA Disposition of Approval Page 7 of 13 406 Pearl Street, 2019 On August 12th, 2020, the Landmarks Board approved a landmark alteration certificate (lac) for the removal of the existing house, construction of 3,295 sq. ft. one and one-half story house the demolition of a non-historic 263 sq. ft. cottage, the demolition of small shed and construction of 400 sq. ft., two-car garage at southeast corner of property and preservation of the historic barn. Approved Proposal for construction of house and garage at 406 Pearl Street (HIS2020-00163) (re-location of barn was not part of this review) Because the historic barn is currently located in the 100-year flood zone and encroaching over the west property line into the city’s right-of-way, on June 2nd, 2021 the Landmarks Board approved the relocation and raising of that building finding that these steps were necessary to preserve the building and that they meet the standards for issuance of an lac (Section 9-11-18, B.R.C. 1981) and consistent with the General Design Guidelines and the West Pearl Historic District Design Guidelines. BOZA Disposition of Approval Page 8 of 13 Approved Site Plan for Relocation and New Construction at 406 Pearl Street (HIS2021-00117) In its motion to approve the proposal, the Landmarks Board included support for a variance under 9-2-3(h)(4) Designated Historic Property of the Boulder Revised Code, finding that in that relocating the barn in a “by-right” location would have an adverse effect on the historic character of the barn and West Pearl Historic District. The Landmarks Design Review Committee’s Support The Landmarks Board supports the requested variances to the rear (south) setback along the alley and side (west) setback facing 4th Street under 9.2.3(h)(4) Designated Historic Property, of the Boulder Revised Code, finding that relocating the garage to a by-right location would likely have an adverse effect on the historic character of the contributing barn and property in the West Pearl Historic District. Please feel free to contact me at 303.441.3209 if you have questions or need more information. BOZA Disposition of Approval Page 9 of 13 JOB# 2011406 Pearl StreetCADDesigns 3/10/2021 BARN COVER SHEET issued: drawn by: revised: B-1 sheet 406 Pearl StreetBoulder, CO 803021701 15th Street, Unit ABoulder, CO 80302(303) 304-0868Samuel Austin & CompanyArchitects, Inc. NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor, and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect, and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for all consequences. Changes made from the plans without the consent of the architect are unauthorized, and shall relieve the architect of responsibility for all consequences arising out of such changes. 8/23/20211 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) BOULDER REVISED CODE, 1981 (B.R.C.) - TITLE 10 STRUCTURES BOULDER REVISED CODE, 1981 - TITLE 9 LAND USE CODE 2018 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE (IWUIC) 2020 CITY OF BOULDER ENERGY CONSERVATION CODE (COBECC) 2020 NATIONAL ELECTRICAL CODE (as of August 1, 2020) CITY OF BOULDER DESIGN AND CONSTRUCTION STANDARDS SHEET INDEX 1 1 GENERAL NOTES 1 ALL CONSTRUCTION TO BE COMPLETED PER GOVERNING CODES. 2 ALL EXTERIOR WALLS TO BE 2X6 CONSTRUCTION AND INTERIOR WALLS TO BE 2X4 CONSTRUCTION EXCEPT AS NOTED ON THESE AND STRUCTURAL PLANS. 3 ALL GL ASS 18" A .F.F. OR LESS AND IN OTHER HAZARDOUS LOCATIONS IS TO BE TEMPERED. 4 PROVIDE BLOCKING AT ALL CABINETRY, CLOSET RODS AND SHELF & BRACKET LOCATIONS, HANDRAILS, SHOWER ENCLOSURES, DOORS & TUB ENCLOSURES. 5 SEE STRUCTURAL PL ANS FOR ALL STRUCTURAL NOTES, SIZES, AND DETAILS. 6 PROVIDE 26 GAUGE FL ASHING BET WEEN EXTERIOR CONCRETE SL ABS AND WOOD FRAMING. 7 GROUND FAULT INTERRUPTER (GFI) PROTECTION IS TO BE PROVIDED TO ALL BATH, KITCHEN, GARAGE, AND EXTERIOR OUTLETS. 8 ALL EXTERIOR OUTLETS TO BE WEATHER PROOF. 9 PROVIDE SWITCHED LIGHT IN ATTIC AT ATTIC ACCESS, AND IN CRAWL SPACE AT CRAWL SPACE ACCESS. 10 PROVIDE ROOF VENTS AND SOFFITS TO PROVIDE 1:300 OF ATTIC AREA AS VENTS. 11 GUTTERS AND DOWNSPOUTS SHOWN: INSTALL GUTTERS ON ALL HORIZONTAL FASCIAS PER CODE. 12 ALL WINDOW SIZES, ROUGH OPENINGS, OPERATION , MANUFACTURER, AND SPECIFICATIONS BY SIGNATURE WINDOWS TO BE VERIFIED BY THE GENERAL CONTRACTOR. SEE DETAILS FOR ROUGH OPENINGS. 13 ALL DIMENSIONS ARE TO ROUGH FRAMING U.O.N. 14 ROOF SURFACE TO BE COVERED WITH ICE AND WATER SHIELD PER CODE. 15 ALL EXTERIOR LIGHTS ARE DOWN LIGHTS AND COMPLY WITH "DARK SKY SPECIFICATIONS". 16 WINDOWS TO HAVE MINIMUM U-VALUE OF .30. 17 ALL SPRAY FOAM INSUL ATION OPEN OR CLOSED MUST BE PROTECTED BY 1/2" GYP WALL BOARD OR EQUAL MATERIAL MEETING FIRE TEST NFPA 275. 18 SPRINKLER SYSTEM AND PL AN TO BE PROVIDED BY THE GENERAL CONTRACTOR AND APPROVED BY THE OWNER AND ARCHITECT 19 CONTINUOUS AIR BARRIER REQUIRED WHEREVER EXTERIOR BECOMES EXPOSED DURING CONSTRUCTION. 20 ATTIC INSUL ATION TO BE MINIMUM R-49. 21 THE SITE PL AN IS ALWAYS BASED ON A SURVEY. 22 CONCRETE ENCASED ELECTRODES ARE REQUIRED. ELECTRICIAN TO SUGGEST LOCATION. 23 FIRE SUPRESSION REQUIRED FOR BUILDING. CONSULTANT INFORMATION ARCHITECT: SAMUEL AUSTIN & COMPANY ARCHITECTS, INC. 1701 15 ST., UNIT A BOULDER, CO 80302 303-304-0868 GENERAL CONTRACTOR: ONE CALL CONSTRUCTION 303-819-0971 STRUCTURAL ENGINEER: ASCENT GROUP STRUCTURAL ENGINEERING 6707 WINCHESTER CIRCLE, SUITE 100 BOULDER, CO 80301 303-499-3022 SURVEYOR: FL ATIRONS, INC. 3825 IRIS AVENUE, SUITE 395 BOULDER, CO 80301 303-443-7001 SOILS ENGINEER: CUSHMAN GEOSCIENCE P.O. BOX 300626 DENVER, CO 80203 303-475-7993 ENERGY CONSULTANT: ENERGY LOGIC 303-885-6066 LANDSCAPE ARCHITECT: STONELEAF DESIGN, L.L.C. 1701 SHORT PL ACE LONGMONT, CO 80501 732-597-3384 MMC G-1 MANDATORY MEASURES CHECKLISTS COVER SHEET 1 1 1 1 1 125.0' SETBACK 54.6' 29.6'4.0'6.8'±WALL TO WALL1.0'0.1'6.5'±FASCIA TO FASCIA5391.36T .O . S L A B 1 0 0 '-0 " = 5 3 9 1 .7 4 T.O. WALL5393.55393.05394.0 5393.5 5 3 9 4 .0 5392.5T .O . F O U N D A T IO N 1 0 3 '-6 " 5 3 9 5 .2 4 5 3 9 1 .5 6 B.O. WALL5392.0SP-4 5390 5391 5391 5392 N15°36'54"W 139.51' (C) NEW BARN LOCATION LOT 7 & LOT 8 BLK 59 20' ALLEY 140'(P) OVERHEAD UTILITIES OVERHEAD UTILITIES PATIO MAIN FLOOR 100'-0" = 5395.0 U.S.G.S. EXISTING CURB CUTS TO BE REMOVED AND CLOSED PER CITY STANDARDS 5 3 9 1 .2 4 5 3 9 4 .5 6 NEW 5'-0" TALL FENCE EXISTING TREE TO BE REMOVED NEW CONCRETE DRIVEWAY NEW BURIED ELECTRIC LINE EXISTING UTILITY POLE ROOF ABOVE EXISTING BARN LOCATION EXISTING TOP OF FLOOR = 5391.5± NEW RETAINING WALL WALL - SEE LANDSCAPE PLAN S74°51'00"W 50.30' (C)50'(P)5391.3 LOW POINT 25' FROM HOUSE STEPS FIREPIT CLEANOUTS GARAGE UNDER SEPARATE PERMIT SCHEDULE 40 PVC 5389.6 LOW POINT 25' FROM PROPOSED BARN LOCATION STEPS SP-3 SITE DEMOLITION PL AN, L ANDSCAPE PL AN 1 2 G-2 2 G-2 10 B-2 6 G-2 4 G-2 5 G-2 3 G-2 2 B-2 4 B-2 1 B-2 6"6" 6"6"6'-5 3/4"±FASCIA TO FASCIA6'-7 1/4"±FASCIA TO FASCIA6'-10 1/4"±WALL TO WALLBARN SLOPE TO MATCHEXISTING BARNROOF - FILED VERIFYSLOPE TO MATCHEXISTING BARNROOF - FILED VERIFYNSCALE: 1" = 10'1 Site Plan 0 5'10'20'SCALE: 1/4" = 1'-0"2 Roof Plan 0 2'4'8' 406 Pearl Street Barn 406 Pearl Street, Boulder, CO 80302 ZONING RMX-1 CONSTRUCTION TYPE V OCCUPANCY R-3 STORIES 1 MAX. EXISTING HT 34.39' from low point LOT AREA 7,017 SF LEVEL OF ALTERATION/ SCOPE OF WORK New Construction of Single Family Residence with Detached Garage LOT 6 BLK 59 BOULDER WEST County of Boulder, State of Colorado CODE REVIEW LEGAL DESCRIPTION APPLICABLE CODES BOZA Disposition of Approval Page 10 of 13 BOZA Disposition of Approval Page 11 of 13 JOB# 2011406 Pearl StreetCADDesigns 3/10/2021 SITE DEMOLITION PLAN, LANDSCAPE PLAN issued: drawn by: revised: SP-3 sheet 406 Pearl StreetBoulder, CO 803021701 15th Street, Unit ABoulder, CO 80302(303) 304-0868Samuel Austin & CompanyArchitects, Inc. NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor, and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect, and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for all consequences. Changes made from the plans without the consent of the architect are unauthorized, and shall relieve the architect of responsibility for all consequences arising out of such changes. 8/23/20211 EXISTING METERS GAS METER WATER METER N15°36'54"W 139.51' (C) S15°36'54"E 139.51' (C)N74°51'00"E 50.30' (C)EXISTING COTTAGE TO BE DEMOLISHED GAS METER EXISTING HOUSE TO BE REMOVED SEE LANDSCAPING DESIGNER PLANS FOR FINAL HARDSCAPING, RETAINING WALLS, BOULDERS, FENCES, GRADE ELEVATIONS, STEPS, ETC. AND THEIR COVERAGES SEE DEMOLITION PLAN FOR STRUCTURES AND LANDSCAPE ELEMENTS TO BE REMOVED EXISTING FENCE TO BE REPL ACED EXISTING FENCE TO BE REPL ACED EXISTING SIDEWALKS TO REMAIN EXISTING BARN TO BE RELOCATED TO THIS LOCATION EXISTING SHED TO BE DEMOLISHED EXISTING FENCE TO BE REPL ACED EXISTING DRIVEWAY TO BE REMOVED VERIFY EXISTING UTILITY LOCATIONS UPGRADE EXISTING WATER METER TO 1" WATER METER EXISTING TREE TO BE REMOVEDWALKS TO BE REMOVED WALKS TO BE REMOVED EXISTING OVERHEAD LINES TO BE BURIEDS74°51'00"W 50.30' (C)5393.485394.585391.365 3 9 0 .7 6 5391.745392.325394.05393.95 5393.36 5391.86 5393.545396.895396.895396.89 5393.00 5391.305391.91 5392.72' T .O . S L A B 1 0 0 '-0 " = 5 3 9 1 .7 4 T.O. WALL5393.55393.05394.0 5393.5 5 3 9 4 .0 5392.5T .O . F O U N D A T IO N 1 0 3 '-6 " 5 3 9 5 .2 4 5 3 9 1 .5 6 B.O. WALL5392.0WATER METER 5390 5391 5391 5392 5392 5393 53935394 N15°36'54"W 139.51' (C) S15°36'54"E 139.51' (C)N74°51'00"E 50.30' (C)SEE LANDSCAPING DESIGNER PLANS FOR FINAL HARDSCAPING, RETAINING WALLS, BOULDERS, FENCES, GRADE ELEVATIONS, STEPS, ETC. AND THEIR COVERAGES 18" 18" 18" 18" 24" 24" 30" 30" 30" 30" 30" 36" 42" SEE DEMOLITION PLAN FOR STRUCTURES AND LANDSCAPE ELEMENTS TO BE REMOVED NEW FENCE - 1" GAPSNEW FENCE - 1" GAPS NEW FENCE - 0" GAPS MAIN FLOOR 100'-0" = 5397.2 5394 NEW 3'-0" WIDE X 4'-6" TALL GATE - 0" GAPS NEW 5' TALL FENCE AND GATE RAISED GARDEN BED NEW IMPERVIOUS COVERAGE SITE AREA = 7,017.44 S.F. HOUSE, STEPS AND PATIOS = 2,994 S.F. GARAGE, DRIVEWAY = 412 S.F. BARN = 402 S.F. TOTAL = 3,808 S.F. - 54.2% EXISTING IMPERVIOUS COVERAGE SITE AREA = 7,017.44 S.F. BUILDINGS, SHEDS ONLY = 1,858 S.F. - 26.4% VERIFY EXISTING UTILITY LOCATIONS NEW 3'-0" WIDE X 3'-6" TALL GATE - 2" GAPS NEW 3'-0" WIDE X 3'-6" TALL GATE - 2" GAPS NEW WROUGHT IRON FENCE NEW VINE STRUCTURE UPGRADE EXISTING WATER METER TO 1" WATER METER 5 3 9 1 .2 4 5 3 9 4 .5 6 S74°51'00"W 50.30' (C)NEW FENCE - 1" GAPSSEE LANDSCAPING PLANS5" WIDE WOOD PLANKS 4"X4" METAL POSTS AT 6'-0" MAXIMUM 1" GAP BET WEEN PL ANKS1X2 METAL CROSS BARS CONCRETE FOOTING 3'-0"6'-0"2X4 CONCRETE FOOTING CEDAR PL ANKS 4X4 POST 2X4 EXISTING GRADE SCALE: 1" = 10'1 Site Plan - Demolition SCALE: 1" = 10'2 Landscape Plan SCALE: 1" = 1'-0"3 Fence SCALE: 1" = 1'-0"4 Fence 6'-0" BOZA Disposition of Approval Page 12 of 13 JOB# 2011406 Pearl StreetCADDesigns 3/10/2021 BARN FLOOR PLAN AND ELEVATIONS issued: drawn by: revised: B-2 sheet 406 Pearl StreetBoulder, CO 803021701 15th Street, Unit ABoulder, CO 80302(303) 304-0868Samuel Austin & CompanyArchitects, Inc. NOTICE: DUTY OF COOPERATION Release of these plans contemplates further cooperation among the owner, his contractor, and the architect. Design and construction are complex. Although the architect and his consultants have performed their services with due care and diligence, they cannot guarantee perfection. Communication is imperfect, and every contingency cannot be anticipated. Any ambiguity or discrepancy discovered by the use of these plans shall be reported immediately to the architect. Failure to notify the architect compounds misunderstanding and increases construction costs. A failure to cooperate by a simple notice to the architect shall relieve the architect from responsibility for all consequences. Changes made from the plans without the consent of the architect are unauthorized, and shall relieve the architect of responsibility for all consequences arising out of such changes. 8/23/20211 DB01 24" WIDE WALL HUNG SINK BEAM ABOVE SLIDING BARN DOOR DB02 CONCRETE LANDING WINDOWS TIGHT TO COLUMN 18" UC.REF.30" COOKTOP WITHEXHAUST HOODREMOVE AND REPLACEEXISTING WINDOW -MATCH SIZE - VERIFY SIZESAUNA NEW WINDOW 4'-0"X6'-8" NEW WINDOWS 23'-1 1/4"EXISTING - VERIFY20'-6" EXISTING - VERIFY 3 1/2"3'-0"6'-9"5 1/2"9'-1 1/2"±3 1/2"3 1/2"3 1/2"3'-3"3 1/2"2'-7"±3'-10"EQUALEQUALEQUALEQUAL10 B-2 10 B-2 2 B-2 6 B-2 4 B-2 1 B-2 DB03 WB01 WB02 WB03 NEW 2X4 WALLS WITH INSUL ATION AT INSIDE OF EXISTING WALLS TANKLESS WATER HEATER ABOVE TOILET BUILT INS NEW STEPS - 7 1/2" MAXIMIM RISE 10" TREADS HANDRAIL AND GUARD RAIL PER CODE NEW 4X10 BEAMS ABOVE REMOVE THIS EXISTING WALL AND DOOR NEW RETAINING WALL REMOVE AND REPL ACE EXISTING WINDOWS - MATCH SIZES - VERIFY SIZES NEW 4" CONCRETE SLAB THROUGHOUT ON BLUE BOARD INSULATION EXERCISE ROOM NEW ENTRY DOOR EXISTING 6" VERTICAL SIDING EXISTING DOOR EXISTING 6" CORNER TRIM EXISTING PAINTING EXISTING WINDOWS AND TRIM EXISTING CORBELS EXSITING ROOFING EXISTING TURNED COLUMN EXISTING 6" VERTICAL SIDING EXISTING 10" HORIZONTAL SIDING EXISTING ROOFING EXISTING ROOFING EXISTING 4X4 COLUMNS EXISTING 6" VERTICAL SIDING EXISTING CORRUGATED METAL VERTICAL SIDING EXISTING 10" HORIZONTAL SIDING EXISTING CORBELS EXISTING 6" FRIEZE TRIM EXISTING ROOFING T.O. EXISTING FLOOR 5391.5± U.S.G.S. EXISTING 6" HORIZONTAL SIDING EXISTING CORBELS EXISTING 6" VERTICAL SIDING EXISTING LOFT DOOR EXISTING 6" CORNER TRIM EXISTING 6" CORNER TRIM EXISTING DOOR EXISTING 6" TRIM EXISTING 6" FRIEZE TRIM J 220 3 G D SC 4 TV DUPLEX RECEPTACLE OUTLET FLOOR MOUNTED WP RECESSED CAN FIXTURE SURFACE MOUNTED OR HANGING FIXTURE ELECTRICAL SYMBOLS KEY FLUORESCENT SURFACE MOUNTED FIXTURE TRACK LIGHT DUPLEX RECEPTACLE OUTLET / UNDER COUNTER OUTLET WATERPROOF DUPLEX RECEPTACLE OUTLET DUPLEX RECEPTACLE OUTLET SPLIT WIRED DIMMER SWITCH QUADRUPLEX RECEPTACLE OUTLET 220 VOLT OUTLET CABLE TELEVISION OUTLET TELEPHONE OUTLET SINGLE SWITCH GARAGE DOOR OPENER CEILING EXHAUST FAN THREE-WAY SWITCH LANDSCAPE LIGHT WALL MOUNTED FIXTURE / WALL SCONCE RECESSED CAN FIXTURE (WALL WASH) CEILING FAN W/ LIGHTS NOTE:ALL FIXTURE AND OUTLET LOCATIONS SUBJECT TO CODE COMPLIANCE AND STRUCTURAL FRAMING MEMBER LOCATIONS JUNCTION BOX 4 SMOKE AND CARBON MONOXIDE DETECTOR LED STRIP FIXTURE FOUR-WAY SWITCH DB01 DB02 DB03 2'-6" 4'-0" 3'-0" 6'-8" 8'-0" 6'-8" WB01 WB02 WB03 1'-6" 1'-6" 5'-0" 4'-0" 4'-0" 4'-0" Casement Casement Casement WINDOW SCHEDULE No.Width Height Type Note/Remarks DOOR SCHEDULE No.Width Height Notes/Remarks 7'-6"3"NEW 2X4 WALLS WITH INSULATION AT INSIDE OF EXISTING WALLS NEW 4" CONCRETE SL AB THROUGHOUT ON BLUE BOARD INSUL ATION NEW FOUNDATION WALLS NEW 4X10 BEAMS RAISE WINDOW TO 3" ABOVE BEAMS EXISTING 6" VERTICAL SIDING EXISTING 10" HORIZONTAL SIDING EXISTING ROOFING EXISTING ROOFING WB01WB02WB03 MAIN LEVEL T.O. SUBFLOOR 5395.0 5389.6 LOW POINT 25' FROM NEW BARN THREAD IN EXISTING AND RECL AIMED BARNWOOD - PAINT TO MATCH PROPOSED GRADE NEW STONE VENEER AND CAP TO MATCH HOUSE EXISTING 4X4 COLUMNSLIGHT WEIGHT PANEL LIGHT WEIGHT CONCRETE PANEL REGLET JOINT 3'-0"±19.8' N.T.S.MAIN LEVEL T.O. SUBFLOOR 5395.0 REMOVE AND REPLACE EXISTING WINDOWS - MATCH SIZES - VERIFY SIZES 5389.6 LOW POINT 25' FROM NEW BARN 5409.4' BASED ON SURVEYED RIDGE ELEVATION THREAD IN EXISTING AND RECLAIMED BARNWOOD - PAINT TO MATCH NEW STONE VENEER AND CAP TO MATCH HOUSE RETAINING WALL WITH STONE VENEER AND STONE CAP EXISTING 6" HORIZONTAL SIDING EXISTING CORBELS EXISTING 6" VERTICAL SIDING EXISTING LOFT DOOR EXISTING 6" CORNER TRIM NEW 6" CORNER TRIM EXISTING 6" CORNER TRIM NEW 6" CORNER TRIM EXISTING DOOR EXISTING 6" TRIM EXISTING 6" FRIEZE TRIM EXISTING 6" VERTICAL SIDING 3'-0"REMOVE AND REPLACE EXISTING WINDOWS - MATCH SIZE - VERIFY SIZE MAIN LEVEL T.O. SUBFLOOR 5395.0 5389.6 LOW POINT 25' FROM NEW BARN THREAD IN EXISTING AND RECL AIMED BARNWOOD - PAINT TO MATCH RETAINING WALL WITH STONE VENEER AND STONE CAP EXISTING DOOR EXISTING 6" CORNER TRIM NEW 6" CORNER TRIM EXISTING PAINTING EXISTING WINDOWS AND TRIM EXISTING CORBELS EXSITING ROOFING EXISTING TURNED COLUMN 5393.0+ EXISTING 6" VERTICAL SIDING NEW STEPS - 7 1/2" MAXIMIM RISE 11" TREADS HANDRAIL AND GUARD RAIL PER CODE MAIN LEVEL T.O. SUBFLOOR 5395.0 REMOVE AND REPLACE EXISTING WINDOWS - MATCH SIZES - VERIFY SIZES 5389.6 LOW POINT 25' FROM NEW BARN THREAD IN EXISTING AND RECL AIMED BARNWOOD - PAINT TO MATCH STONE VENEER AND STONE CAP EXISTING CORRUGATED METAL VERTICAL SIDING EXISTING 10" HORIZONTAL SIDING EXISTING CORBELS NEW CORRUGATED METAL VERTICAL SIDING EXISTING 6" FRIEZE TRIM EXISTING ROOFING NSCALE: 1/4" = 1'-0"11 Barn Main Level Floor Plan 0 2'4'8' SCALE: 1/4" = 1'-0"7 Barn Existing West Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"3 Barn Existing East Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"5 Barn Existing North Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"1 Barn Existing South Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"9 Barn Main Level Electrical Plan SCALE: 1/4" = 1'-0"10 Barn Section SCALE: 1/4" = 1'-0"2 Barn New East Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"8 Barn New South Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"6 Barn New West Elevation 0 2'4'8' SCALE: 1/4" = 1'-0"4 Barn New North Elevation 0 2'4'8' BOZA Disposition of Approval Page 13 of 13